{"title":"AC Contactors","description":"\u003cp\u003eThe contactor is the relay that switches high voltage to the compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn from arcing, and ants and wasps get into them.\u003c\/p\u003e\u003cp\u003eSymptoms: the outdoor unit does nothing while the indoor blower runs, a loud chatter or buzz from the disconnect area, or contacts that are visibly burnt, welded shut, or stuck. Match the pole count and the coil voltage (usually 24V) to the one you are removing.\u003c\/p\u003e\u003cp class=\"fd-coll-terms\"\u003eShips the same business day on orders placed by 2 PM CT. 7-day returns on parts. Not sure which one you need? Call \u003cstrong\u003e(888) 762-1334\u003c\/strong\u003e — we are licensed HVAC contractors (Hamlin Mechanical LLC, MN Lic. #128688) and we would rather talk you out of the wrong part than sell it to you.\u003c\/p\u003e","products":[{"product_id":"contactor-m91411","title":"Contactor — 24V, 1-Pole | M91411","description":"\u003cp\u003e\u003cstrong\u003eContactor — 24V, 1-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM91411\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM91411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380537647,"sku":"M91411","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M91411.jpg?v=1785719540"},{"product_id":"contactor-m91421","title":"Contactor — 2-Pole | M91421","description":"\u003cp\u003e\u003cstrong\u003eContactor — 2-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM91421\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM91421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380570415,"sku":"M91421","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M91421.jpg?v=1785719542"},{"product_id":"contactor-m17315","title":"Contactor — 24V, 1-Pole | M17315","description":"\u003cp\u003e\u003cstrong\u003eContactor — 24V, 1-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM17315\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM17315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380603183,"sku":"M17315","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M17315.jpg?v=1785719543"},{"product_id":"contactor-m17325","title":"Contactor — 24V, 2-Pole | M17325","description":"\u003cp\u003e\u003cstrong\u003eContactor — 24V, 2-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM17325\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM17325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380635951,"sku":"M17325","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M17325.jpg?v=1785719544"},{"product_id":"contactor-204502","title":"Contactor — 2-Pole | 204502","description":"\u003cp\u003e\u003cstrong\u003eContactor — 2-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e204502\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e204502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271380668719,"sku":"204502","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/204502.jpg?v=1785719545"},{"product_id":"contactor-204504","title":"Contactor — 1-Pole | 204504","description":"\u003cp\u003e\u003cstrong\u003eContactor — 1-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e204504\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e204504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271380701487,"sku":"204504","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/204504.jpg?v=1785719546"},{"product_id":"contactor-204505","title":"Contactor — 2-Pole | 204505","description":"\u003cp\u003e\u003cstrong\u003eContactor — 2-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e204505\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e204505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271380734255,"sku":"204505","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/204505.jpg?v=1785719547"},{"product_id":"contactor-204503","title":"Contactor — 1-Pole | 204503","description":"\u003cp\u003e\u003cstrong\u003eContactor — 1-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e204503\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e204503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271380767023,"sku":"204503","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/204503.jpg?v=1785719548"}],"url":"https:\/\/furnace.direct\/collections\/contactors\/16-seer2+variable-speed.oembed","provider":"Furnace Direct","version":"1.0","type":"link"}