{"title":"Furnace Gas Valves","description":"\u003cp\u003eThe gas valve meters gas to the burners on command from the control board. This is the part to be careful with — a gas valve is not a guess-and-see repair.\u003c\/p\u003e\u003cp\u003eReplace it when the board is calling for gas, the igniter is glowing, and no gas arrives — with the manifold pressure and 24V at the valve terminals both confirmed. Match the inlet and outlet sizes, the gas type, and the valve type (single-stage, two-stage, combination control). Leak-check every joint on startup.\u003c\/p\u003e\u003cp class=\"fd-coll-terms\"\u003eShips the same business day on orders placed by 2 PM CT. 7-day returns on parts. Not sure which one you need? Call \u003cstrong\u003e(888) 762-1334\u003c\/strong\u003e — we are licensed HVAC contractors (Hamlin Mechanical LLC, MN Lic. #128688) and we would rather talk you out of the wrong part than sell it to you.\u003c\/p\u003e","products":[{"product_id":"furnace-gas-valve-624775r","title":"Furnace Gas Valve | 624775R","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e624775R\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e624775R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Airtemp","offers":[{"title":"Default Title","offer_id":58271394791727,"sku":"624775R","price":655.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/624775R.jpg?v=1785719623"},{"product_id":"furnace-gas-valve-vr8345m4302-u","title":"Furnace Gas Valve | VR8345M4302\/U","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eVR8345M4302\/U\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eVR8345M4302\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":58271394824495,"sku":"VR8345M4302\/U","price":745.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/VR8345M4302-U.jpg?v=1785719624"},{"product_id":"furnace-gas-valve-102-515","title":"Furnace Gas Valve | 102-515","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e102-515\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e102-515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Legend Valve","offers":[{"title":"Default Title","offer_id":58271394857263,"sku":"102-515","price":560.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/102-515.jpg?v=1785719625"},{"product_id":"furnace-gas-valve-vr8300m4406-u","title":"Furnace Gas Valve | VR8300M4406\/U","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eVR8300M4406\/U\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eVR8300M4406\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":58271394890031,"sku":"VR8300M4406\/U","price":765.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/VR8300M4406-U.jpg?v=1785719626"},{"product_id":"furnace-gas-valve-36j22-214","title":"Furnace Gas Valve — 24V | 36J22-214","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve — 24V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e36J22-214\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e36J22-214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"White-Rodgers","offers":[{"title":"Default Title","offer_id":58271394922799,"sku":"36J22-214","price":625.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/36J22-214.jpg?v=1785719627"},{"product_id":"furnace-gas-valve-36c03-300","title":"Furnace Gas Valve | 36C03-300","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e36C03-300\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e36C03-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"White-Rodgers","offers":[{"title":"Default Title","offer_id":58271394955567,"sku":"36C03-300","price":690.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/36C03-300.jpg?v=1785719628"},{"product_id":"furnace-gas-valve-vr8200a2132-u","title":"Furnace Gas Valve | VR8200A2132\/U","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eVR8200A2132\/U\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eVR8200A2132\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Resideo","offers":[{"title":"Default Title","offer_id":58271394988335,"sku":"VR8200A2132\/U","price":705.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/VR8200A2132-U.jpg?v=1785719630"},{"product_id":"furnace-gas-valve-101-025nl","title":"Furnace Gas Valve | 101-025NL","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e101-025NL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e101-025NL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Legend Valve","offers":[{"title":"Default Title","offer_id":58271395021103,"sku":"101-025NL","price":550.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/101-025NL.jpg?v=1785719631"}],"url":"https:\/\/furnace.direct\/collections\/gas-valves\/3-5-ton+variable-speed.oembed","provider":"Furnace Direct","version":"1.0","type":"link"}