{"title":"Furnace Gas Valves","description":"\u003cp\u003eReplacement gas valves for residential furnaces. This is gas work: leak-test every joint and verify manifold pressure with a manometer, or have a licensed technician fit it.\u003c\/p\u003e","products":[{"product_id":"furnace-gas-valve-624775r","title":"Furnace Gas Valve | 624775R","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e624775R\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e624775R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years. Most HVAC companies charge $500-900 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a furnace gas valve?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $500-900 for this repair, including the service call. The part itself is $205.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271394791727,"sku":"624775R","price":205.95,"currency_code":"USD","in_stock":true}]},{"product_id":"furnace-gas-valve-vr8345m4302-u","title":"Furnace Gas Valve | VR8345M4302\/U","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eVR8345M4302\/U\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eVR8345M4302\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years. Most HVAC companies charge $500-900 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a furnace gas valve?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $500-900 for this repair, including the service call. The part itself is $311.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271394824495,"sku":"VR8345M4302\/U","price":311.95,"currency_code":"USD","in_stock":true}]},{"product_id":"furnace-gas-valve-102-515","title":"Furnace Gas Valve | 102-515","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e102-515\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e102-515\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years. Most HVAC companies charge $500-900 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a furnace gas valve?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $500-900 for this repair, including the service call. The part itself is $88.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271394857263,"sku":"102-515","price":88.95,"currency_code":"USD","in_stock":true}]},{"product_id":"furnace-gas-valve-vr8300m4406-u","title":"Furnace Gas Valve | VR8300M4406\/U","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eVR8300M4406\/U\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eVR8300M4406\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years. Most HVAC companies charge $500-900 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a furnace gas valve?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $500-900 for this repair, including the service call. The part itself is $352.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271394890031,"sku":"VR8300M4406\/U","price":352.95,"currency_code":"USD","in_stock":true}]},{"product_id":"furnace-gas-valve-36j22-214","title":"Furnace Gas Valve — 24V | 36J22-214","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve — 24V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e36J22-214\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e36J22-214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years. Most HVAC companies charge $500-900 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a furnace gas valve?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $500-900 for this repair, including the service call. The part itself is $173.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271394922799,"sku":"36J22-214","price":173.95,"currency_code":"USD","in_stock":true}]},{"product_id":"furnace-gas-valve-36c03-300","title":"Furnace Gas Valve | 36C03-300","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e36C03-300\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e36C03-300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years. Most HVAC companies charge $500-900 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a furnace gas valve?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $500-900 for this repair, including the service call. The part itself is $253.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271394955567,"sku":"36C03-300","price":253.95,"currency_code":"USD","in_stock":true}]},{"product_id":"furnace-gas-valve-vr8200a2132-u","title":"Furnace Gas Valve | VR8200A2132\/U","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eVR8200A2132\/U\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eVR8200A2132\/U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years. Most HVAC companies charge $500-900 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a furnace gas valve?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $500-900 for this repair, including the service call. The part itself is $259.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271394988335,"sku":"VR8200A2132\/U","price":259.95,"currency_code":"USD","in_stock":true}]},{"product_id":"furnace-gas-valve-101-025nl","title":"Furnace Gas Valve | 101-025NL","description":"\u003cp\u003e\u003cstrong\u003eFurnace Gas Valve\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e101-025NL\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe gas valve meters fuel to the burners and holds the safety closed until the control board proves ignition. It is the last part in the chain to suspect -- igniters, flame sensors and pressure switches fail far more often and cost far less.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eNo gas at the burners with a confirmed call for heat and a working igniter\u003c\/li\u003e\n\u003cli\u003eValve does not click or energise when the board calls\u003c\/li\u003e\n\u003cli\u003eManifold pressure reads wrong on a manometer\u003c\/li\u003e\n\u003cli\u003eValve body is visibly damaged or leaking\u003c\/li\u003e\n\u003cli\u003eVerified 24V at the valve terminals with no response\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e101-025NL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced\u003c\/strong\u003e — about 90 minutes. Tools: Pipe wrenches, gas leak detector, manometer. Power off at the breaker: yes. Gas shutoff required: yes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 15-20 years. Most HVAC companies charge $500-900 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my furnace gas valve is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: no gas at the burners with a confirmed call for heat and a working igniter; valve does not click or energise when the board calls; manifold pressure reads wrong on a manometer.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a furnace gas valve myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a advanced repair that takes about 90 minutes with pipe wrenches, gas leak detector, manometer. Always shut the power off at the breaker first. This is gas work. Shut the gas off at the manual valve, leak-test every joint with solution or a detector after reassembly, and verify manifold pressure with a manometer. If you are not equipped to do all three, have a licensed technician fit this part.\u003c\/p\u003e\n\u003ch3\u003eHow long does a furnace gas valve last?\u003c\/h3\u003e\u003cp\u003eTypically 15-20 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a furnace gas valve?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $500-900 for this repair, including the service call. The part itself is $64.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271395021103,"sku":"101-025NL","price":64.95,"currency_code":"USD","in_stock":true}]}],"url":"https:\/\/furnace.direct\/collections\/gas-valves\/variable-speed+two-stage.oembed","provider":"Furnace Direct","version":"1.0","type":"link"}