{"title":"HVAC Replacement Parts","description":"\u003cp\u003eReplacement parts for gas furnaces and central air conditioners, shipped direct. These are the same parts a contractor installs — the difference is you are paying the part price instead of the part price plus a service call.\u003c\/p\u003e\u003cp\u003eStart with the symptom. No flame and no heat is usually the igniter, flame sensor or gas valve. A humming outdoor unit that will not spin is almost always the run capacitor. Water on the floor is the condensate drain. Water in the basement with the unit locked out is the float switch doing its job.\u003c\/p\u003e\u003cp class=\"fd-coll-terms\"\u003eShips the same business day on orders placed by 2 PM CT. 7-day returns on parts. Not sure which one you need? Call \u003cstrong\u003e(888) 762-1334\u003c\/strong\u003e — we are licensed HVAC contractors (Hamlin Mechanical LLC, MN Lic. #128688) and we would rather talk you out of the wrong part than sell it to you.\u003c\/p\u003e","products":[{"product_id":"hot-surface-igniter-21d64-2","title":"Hot Surface Igniter — 120V | 21D64-2","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter — 120V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e21D64-2\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e120V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e21D64-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"White-Rodgers","offers":[{"title":"Default Title","offer_id":58271378473263,"sku":"21D64-2","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/21D64-2.jpg?v=1785719499"},{"product_id":"hot-surface-igniter-1046638s","title":"Hot Surface Igniter | 1046638S","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e1046638S\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e1046638S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Airtemp","offers":[{"title":"Default Title","offer_id":58271378506031,"sku":"1046638S","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/1046638S.jpg?v=1785719500"},{"product_id":"hot-surface-igniter-m68040","title":"Hot Surface Igniter | M68040","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM68040\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM68040\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271378538799,"sku":"M68040","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M68040.jpg?v=1785719501"},{"product_id":"hot-surface-igniter-41-408","title":"Hot Surface Igniter | 41-408","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e41-408\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e41-408\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":58271378964783,"sku":"41-408","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/41-408.jpg?v=1785719502"},{"product_id":"hot-surface-igniter-41-402","title":"Hot Surface Igniter | 41-402","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e41-402\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e41-402\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":58271379194159,"sku":"41-402","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/41-402.jpg?v=1785719503"},{"product_id":"hot-surface-igniter-41-409","title":"Hot Surface Igniter | 41-409","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e41-409\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e41-409\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":58271379226927,"sku":"41-409","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/41-409.jpg?v=1785719504"},{"product_id":"hot-surface-igniter-41-412","title":"Hot Surface Igniter | 41-412","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e41-412\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e41-412\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":58271379259695,"sku":"41-412","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/41-412.jpg?v=1785719506"},{"product_id":"hot-surface-igniter-fc035","title":"Hot Surface Igniter | FC035","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eFC035\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eFC035\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Surface Igniter","offers":[{"title":"Default Title","offer_id":58271379292463,"sku":"FC035","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/FC035.jpg?v=1785719507"},{"product_id":"hot-surface-igniter-41-401","title":"Hot Surface Igniter | 41-401","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e41-401\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e41-401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":58271379325231,"sku":"41-401","price":65.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/41-401.jpg?v=1785719508"},{"product_id":"hot-surface-igniter-41-403","title":"Hot Surface Igniter | 41-403","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e41-403\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e41-403\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":58271379357999,"sku":"41-403","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/41-403.jpg?v=1785719509"},{"product_id":"hot-surface-igniter-41-405","title":"Hot Surface Igniter | 41-405","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e41-405\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e41-405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Robertshaw","offers":[{"title":"Default Title","offer_id":58271379390767,"sku":"41-405","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/41-405.jpg?v=1785719510"},{"product_id":"hot-surface-igniter-ssn3000","title":"Hot Surface Igniter | SSN3000","description":"\u003cp\u003e\u003cstrong\u003eHot Surface Igniter\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eSSN3000\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe hot surface igniter glows red-hot to light the gas burners when your furnace calls for heat. When it cracks or burns out, the furnace runs its inducer and blower but never lights, so you get air movement and no heat.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace runs but never ignites\u003c\/li\u003e\n\u003cli\u003eYou hear the inducer start, but no flame follows\u003c\/li\u003e\n\u003cli\u003eIgniter glows dim orange instead of bright white-orange\u003c\/li\u003e\n\u003cli\u003eIgniter is visibly cracked, chipped, or blistered white\u003c\/li\u003e\n\u003cli\u003eControl board flashes an ignition-failure or lockout code\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eSSN3000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: 1\/4\" nut driver, screwdriver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 3-7 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my hot surface igniter is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace runs but never ignites; you hear the inducer start, but no flame follows; igniter glows dim orange instead of bright white-orange.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a hot surface igniter myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with 1\/4\" nut driver, screwdriver. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a hot surface igniter last?\u003c\/h3\u003e\u003cp\u003eTypically 3-7 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Supco","offers":[{"title":"Default Title","offer_id":58271379423535,"sku":"SSN3000","price":105.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/SSN3000.jpg?v=1785719511"},{"product_id":"run-capacitor-m12786","title":"Dual Run Capacitor — 40\/5 MFD, 440V, Round | M12786","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12786\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12786\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379456303,"sku":"M12786","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12786.jpg?v=1785719512"},{"product_id":"run-capacitor-m12783","title":"Dual Run Capacitor — 35\/5 MFD, 440V, Round | M12783","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12783\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12783\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379489071,"sku":"M12783","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12783.jpg?v=1785719513"},{"product_id":"run-capacitor-m12788","title":"Dual Run Capacitor — 45\/5 MFD, 440V, Round | M12788","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12788\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379521839,"sku":"M12788","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12788.jpg?v=1785719514"},{"product_id":"run-capacitor-m12781","title":"Dual Run Capacitor — 30\/5 MFD, 440V, Round | M12781","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12781\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12781\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379751215,"sku":"M12781","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12781.jpg?v=1785719515"},{"product_id":"run-capacitor-203021","title":"Dual Run Capacitor — 45\/5 MFD, 440V, Round | 203021","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 370\/440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e203021\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e203021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271379783983,"sku":"203021","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/203021.jpg?v=1785719516"},{"product_id":"run-capacitor-m12789","title":"Dual Run Capacitor — 45\/7.5 MFD, 440V | M12789","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12789\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379816751,"sku":"M12789","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12789.jpg?v=1785719517"},{"product_id":"run-capacitor-203018","title":"Dual Run Capacitor — 35\/5 MFD, 440V, Round | 203018","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 370\/440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e203018\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e203018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271379849519,"sku":"203018","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/203018.jpg?v=1785719518"},{"product_id":"run-capacitor-m12932","title":"Run Capacitor — 10 MFD, 440V, Oval | M12932","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 10\/440V, Oval\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12932\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e10\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eOval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12932\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379882287,"sku":"M12932","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12932.jpg?v=1785719520"},{"product_id":"run-capacitor-203020","title":"Dual Run Capacitor — 40\/5 MFD, 440V, Round | 203020","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 370\/440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e203020\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e203020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271379915055,"sku":"203020","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/203020.jpg?v=1785719521"},{"product_id":"run-capacitor-m12931","title":"Run Capacitor — 7.5 MFD, 440V, Oval | M12931","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Oval\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12931\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eOval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12931\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379947823,"sku":"M12931","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12931.jpg?v=1785719522"},{"product_id":"run-capacitor-203012","title":"Run Capacitor — 370\/440V, Oval | 203012","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 370\/440V, Oval\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e203012\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eOval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e203012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271379980591,"sku":"203012","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/203012.jpg?v=1785719523"},{"product_id":"run-capacitor-m12790","title":"Dual Run Capacitor — 50\/5 MFD, 440V, Round | M12790","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12790\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380013359,"sku":"M12790","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12790.jpg?v=1785719524"},{"product_id":"run-capacitor-m12929","title":"Run Capacitor — 5 MFD, 440V, Oval | M12929","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Oval\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12929\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eOval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380046127,"sku":"M12929","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12929.jpg?v=1785719525"},{"product_id":"run-capacitor-m12787","title":"Dual Run Capacitor — 40\/7.5 MFD, 440V | M12787","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12787\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12787\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380078895,"sku":"M12787","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12787.jpg?v=1785719526"},{"product_id":"run-capacitor-m12784","title":"Dual Run Capacitor — 35\/7.5 MFD, 440V | M12784","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12784\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12784\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380111663,"sku":"M12784","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12784.jpg?v=1785719528"},{"product_id":"flame-sensor-790-843a1","title":"Flame Sensor | 790-843A1","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e790-843A1\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e790-843A1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"White-Rodgers","offers":[{"title":"Default Title","offer_id":58271380144431,"sku":"790-843A1","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/790-843A1.jpg?v=1785719529"},{"product_id":"flame-sensor-632484r","title":"Flame Sensor | 632484R","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e632484R\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e632484R\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Airtemp","offers":[{"title":"Default Title","offer_id":58271380177199,"sku":"632484R","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/632484R.jpg?v=1785719530"},{"product_id":"flame-sensor-fls301","title":"Flame Sensor | FLS301","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eFLS301\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eFLS301\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Supco","offers":[{"title":"Default Title","offer_id":58271380275503,"sku":"FLS301","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/FLS301.jpg?v=1785719531"},{"product_id":"flame-sensor-903600","title":"Flame Sensor | 903600","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e903600\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e903600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Airtemp","offers":[{"title":"Default Title","offer_id":58271380308271,"sku":"903600","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/903600.jpg?v=1785719532"},{"product_id":"flame-sensor-98m87","title":"Flame Sensor | 98M87","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e98M87\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e98M87\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Allied Air","offers":[{"title":"Default Title","offer_id":58271380341039,"sku":"98M87","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/98M87.jpg?v=1785719533"},{"product_id":"flame-sensor-fls013","title":"Flame Sensor | FLS013","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eFLS013\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eFLS013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Supco","offers":[{"title":"Default Title","offer_id":58271380373807,"sku":"FLS013","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/FLS013.jpg?v=1785719534"},{"product_id":"flame-sensor-760-401","title":"Flame Sensor | 760-401","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e760-401\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e760-401\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"White-Rodgers","offers":[{"title":"Default Title","offer_id":58271380406575,"sku":"760-401","price":95.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/760-401.jpg?v=1785719535"},{"product_id":"flame-sensor-s1-02527773700","title":"Flame Sensor | S1-02527773700","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eS1-02527773700\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eS1-02527773700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Source One","offers":[{"title":"Default Title","offer_id":58271380439343,"sku":"S1-02527773700","price":65.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/S1-02527773700.jpg?v=1785719536"},{"product_id":"flame-sensor-52m72","title":"Flame Sensor | 52M72","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e52M72\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e52M72\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Allied Air","offers":[{"title":"Default Title","offer_id":58271380472111,"sku":"52M72","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/52M72.jpg?v=1789338876"},{"product_id":"flame-sensor-62-23543-01","title":"Flame Sensor | 62-23543-01","description":"\u003cp\u003e\u003cstrong\u003eFlame Sensor\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e62-23543-01\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe flame sensor is a metal rod that confirms a flame is actually present. It carries a tiny electrical current through the flame; when oxide builds up on the rod that current drops, the control board assumes there is no flame, and it shuts the gas off for safety.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eFurnace lights, runs 3-10 seconds, then shuts down\u003c\/li\u003e\n\u003cli\u003eThe cycle repeats several times, then locks out\u003c\/li\u003e\n\u003cli\u003eFurnace blows cold air after a brief burst of heat\u003c\/li\u003e\n\u003cli\u003eSensor rod is coated white, grey, or sooty\u003c\/li\u003e\n\u003cli\u003eCleaning the rod fixes it for a few weeks, then it returns\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e62-23543-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: 1\/4\" nut driver, fine abrasive pad. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 2-5 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my flame sensor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: furnace lights, runs 3-10 seconds, then shuts down; the cycle repeats several times, then locks out; furnace blows cold air after a brief burst of heat.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a flame sensor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with 1\/4\" nut driver, fine abrasive pad. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a flame sensor last?\u003c\/h3\u003e\u003cp\u003eTypically 2-5 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Fujitsu","offers":[{"title":"Default Title","offer_id":58271380504879,"sku":"62-23543-01","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/62-23543-01.jpg?v=1789338879"},{"product_id":"contactor-m91411","title":"Contactor — 24V, 1-Pole | M91411","description":"\u003cp\u003e\u003cstrong\u003eContactor — 24V, 1-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM91411\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM91411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380537647,"sku":"M91411","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M91411.jpg?v=1785719540"},{"product_id":"contactor-m91421","title":"Contactor — 2-Pole | M91421","description":"\u003cp\u003e\u003cstrong\u003eContactor — 2-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM91421\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM91421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380570415,"sku":"M91421","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M91421.jpg?v=1785719542"},{"product_id":"contactor-m17315","title":"Contactor — 24V, 1-Pole | M17315","description":"\u003cp\u003e\u003cstrong\u003eContactor — 24V, 1-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM17315\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM17315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380603183,"sku":"M17315","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M17315.jpg?v=1785719543"},{"product_id":"contactor-m17325","title":"Contactor — 24V, 2-Pole | M17325","description":"\u003cp\u003e\u003cstrong\u003eContactor — 24V, 2-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM17325\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e24V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM17325\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380635951,"sku":"M17325","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M17325.jpg?v=1785719544"},{"product_id":"contactor-204502","title":"Contactor — 2-Pole | 204502","description":"\u003cp\u003e\u003cstrong\u003eContactor — 2-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e204502\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e204502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271380668719,"sku":"204502","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/204502.jpg?v=1785719545"},{"product_id":"contactor-204504","title":"Contactor — 1-Pole | 204504","description":"\u003cp\u003e\u003cstrong\u003eContactor — 1-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e204504\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e204504\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271380701487,"sku":"204504","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/204504.jpg?v=1785719546"},{"product_id":"contactor-204505","title":"Contactor — 2-Pole | 204505","description":"\u003cp\u003e\u003cstrong\u003eContactor — 2-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e204505\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e2-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e204505\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271380734255,"sku":"204505","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/204505.jpg?v=1785719547"},{"product_id":"contactor-204503","title":"Contactor — 1-Pole | 204503","description":"\u003cp\u003e\u003cstrong\u003eContactor — 1-Pole\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e204503\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe contactor is the heavy-duty relay that switches line voltage to your compressor and condenser fan when the thermostat calls for cooling. Its contacts pit and burn over time, and ants and debris get inside, so it either sticks closed or stops pulling in.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eOutdoor unit will not start though the thermostat calls for cooling\u003c\/li\u003e\n\u003cli\u003eLoud chattering or buzzing from the outdoor unit\u003c\/li\u003e\n\u003cli\u003eContacts look pitted, blackened, or welded together\u003c\/li\u003e\n\u003cli\u003eOutdoor unit runs constantly and will not shut off\u003c\/li\u003e\n\u003cli\u003eInsects or debris found inside the contactor housing\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003ePoles\u003c\/th\u003e\n\u003ctd\u003e1-Pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e204503\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModerate\u003c\/strong\u003e — about 30 minutes. Tools: Nut driver, needle-nose pliers, phone camera for wiring. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my contactor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: outdoor unit will not start though the thermostat calls for cooling; loud chattering or buzzing from the outdoor unit; contacts look pitted, blackened, or welded together.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a contactor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a moderate repair that takes about 30 minutes with nut driver, needle-nose pliers, phone camera for wiring. Always shut the power off at the breaker first. This part carries line voltage. Shut the power off at both the breaker and the outdoor disconnect, and photograph the wiring before you remove anything.\u003c\/p\u003e\n\u003ch3\u003eHow long does a contactor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271380767023,"sku":"204503","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/204503.jpg?v=1785719548"},{"product_id":"condensate-float-switch-97087","title":"Condensate Float Switch | 97087","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e97087\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e97087\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380799791,"sku":"97087","price":75.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/97087.jpg?v=1785719550"},{"product_id":"condensate-float-switch-96106","title":"Condensate Float Switch | 96106","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e96106\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e96106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380832559,"sku":"96106","price":55.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/96106.jpg?v=1785719550"},{"product_id":"condensate-float-switch-83210","title":"Condensate Float Switch | 83210","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e83210\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e83210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380865327,"sku":"83210","price":115.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/83210.jpg?v=1785719551"},{"product_id":"condensate-float-switch-97085","title":"Condensate Float Switch | 97085","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e97085\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e97085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380898095,"sku":"97085","price":85.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/97085.jpg?v=1785719553"},{"product_id":"condensate-float-switch-46347400","title":"Condensate Float Switch | 46347400","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e46347400\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e46347400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Field Controls","offers":[{"title":"Default Title","offer_id":58271380930863,"sku":"46347400","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/46347400.jpg?v=1785719554"}],"url":"https:\/\/furnace.direct\/collections\/hvac-parts\/5-ton+variable-speed.oembed","provider":"Furnace Direct","version":"1.0","type":"link"}