{"title":"AC Run Capacitors","description":"\u003cp\u003eThe run capacitor gives the compressor and condenser fan the phase shift they need to start and keep turning. It is the single most common air-conditioning failure and the cheapest to fix.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eMatch the microfarad rating exactly.\u003c\/strong\u003e It is printed on the side of the old capacitor as µF or MFD — a dual capacitor reads like 45\/5, meaning 45 µF for the compressor and 5 µF for the fan. Voltage (370V or 440V) may go up but never down. Same size and shape is not the same part.\u003c\/p\u003e\u003cp\u003eSymptoms: the outdoor unit hums but the fan does not spin, the fan starts if you push it with a stick, the compressor trips the breaker on start, or the top of the capacitor is domed or leaking.\u003c\/p\u003e\u003cp class=\"fd-coll-terms\"\u003eShips the same business day on orders placed by 2 PM CT. 7-day returns on parts. Not sure which one you need? Call \u003cstrong\u003e(888) 762-1334\u003c\/strong\u003e — we are licensed HVAC contractors (Hamlin Mechanical LLC, MN Lic. #128688) and we would rather talk you out of the wrong part than sell it to you.\u003c\/p\u003e","products":[{"product_id":"run-capacitor-m12786","title":"Dual Run Capacitor — 40\/5 MFD, 440V, Round | M12786","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12786\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12786\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379456303,"sku":"M12786","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12786.jpg?v=1785719512"},{"product_id":"run-capacitor-m12783","title":"Dual Run Capacitor — 35\/5 MFD, 440V, Round | M12783","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12783\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12783\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379489071,"sku":"M12783","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12783.jpg?v=1785719513"},{"product_id":"run-capacitor-m12788","title":"Dual Run Capacitor — 45\/5 MFD, 440V, Round | M12788","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12788\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12788\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379521839,"sku":"M12788","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12788.jpg?v=1785719514"},{"product_id":"run-capacitor-m12781","title":"Dual Run Capacitor — 30\/5 MFD, 440V, Round | M12781","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12781\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12781\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379751215,"sku":"M12781","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12781.jpg?v=1785719515"},{"product_id":"run-capacitor-203021","title":"Dual Run Capacitor — 45\/5 MFD, 440V, Round | 203021","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 370\/440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e203021\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e203021\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271379783983,"sku":"203021","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/203021.jpg?v=1785719516"},{"product_id":"run-capacitor-m12789","title":"Dual Run Capacitor — 45\/7.5 MFD, 440V | M12789","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12789\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12789\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379816751,"sku":"M12789","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12789.jpg?v=1785719517"},{"product_id":"run-capacitor-203018","title":"Dual Run Capacitor — 35\/5 MFD, 440V, Round | 203018","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 370\/440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e203018\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e203018\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271379849519,"sku":"203018","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/203018.jpg?v=1785719518"},{"product_id":"run-capacitor-m12932","title":"Run Capacitor — 10 MFD, 440V, Oval | M12932","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 10\/440V, Oval\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12932\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e10\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eOval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12932\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379882287,"sku":"M12932","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12932.jpg?v=1785719520"},{"product_id":"run-capacitor-203020","title":"Dual Run Capacitor — 40\/5 MFD, 440V, Round | 203020","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 370\/440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e203020\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e203020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271379915055,"sku":"203020","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/203020.jpg?v=1785719521"},{"product_id":"run-capacitor-m12931","title":"Run Capacitor — 7.5 MFD, 440V, Oval | M12931","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Oval\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12931\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eOval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12931\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271379947823,"sku":"M12931","price":25.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12931.jpg?v=1785719522"},{"product_id":"run-capacitor-203012","title":"Run Capacitor — 370\/440V, Oval | 203012","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 370\/440V, Oval\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e203012\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd\u003e370\/440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eOval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e203012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Cambridge Resources","offers":[{"title":"Default Title","offer_id":58271379980591,"sku":"203012","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/203012.jpg?v=1785719523"},{"product_id":"run-capacitor-m12790","title":"Dual Run Capacitor — 50\/5 MFD, 440V, Round | M12790","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Round\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12790\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eRound\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12790\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380013359,"sku":"M12790","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12790.jpg?v=1785719524"},{"product_id":"run-capacitor-m12929","title":"Run Capacitor — 5 MFD, 440V, Oval | M12929","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V, Oval\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12929\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCase Style\u003c\/th\u003e\n\u003ctd\u003eOval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380046127,"sku":"M12929","price":15.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12929.jpg?v=1785719525"},{"product_id":"run-capacitor-m12787","title":"Dual Run Capacitor — 40\/7.5 MFD, 440V | M12787","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12787\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12787\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380078895,"sku":"M12787","price":45.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12787.jpg?v=1785719526"},{"product_id":"run-capacitor-m12784","title":"Dual Run Capacitor — 35\/7.5 MFD, 440V | M12784","description":"\u003cp\u003e\u003cstrong\u003eRun Capacitor — 440V\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003eM12784\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe run capacitor stores and releases the electrical charge that keeps your compressor and condenser fan motor turning. When it weakens, the motor cannot start or hold speed, which is why a failing capacitor is the single most common air-conditioning failure.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eAC hums but the fan does not spin\u003c\/li\u003e\n\u003cli\u003eOutdoor unit trips the breaker on start-up\u003c\/li\u003e\n\u003cli\u003eCapacitor top is domed, bulging, or leaking\u003c\/li\u003e\n\u003cli\u003eAC starts, runs briefly, then shuts off\u003c\/li\u003e\n\u003cli\u003eFan spins if you push it with a stick, but not on its own\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e440V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003eM12784\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 15 minutes. Tools: Insulated screwdriver, nut driver. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety warning:\u003c\/strong\u003e Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-10 years.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my run capacitor is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: ac hums but the fan does not spin; outdoor unit trips the breaker on start-up; capacitor top is domed, bulging, or leaking.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a run capacitor myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 15 minutes with insulated screwdriver, nut driver. Always shut the power off at the breaker first. Capacitors hold a lethal charge even with the power off. Discharge across the terminals with an insulated screwdriver before touching them.\u003c\/p\u003e\n\u003ch3\u003eHow long does a run capacitor last?\u003c\/h3\u003e\u003cp\u003eTypically 5-10 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 7 days of delivery. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"RectorSeal","offers":[{"title":"Default Title","offer_id":58271380111663,"sku":"M12784","price":35.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0955\/2111\/2367\/files\/M12784.jpg?v=1785719528"}],"url":"https:\/\/furnace.direct\/collections\/run-capacitors\/4-ton+5-ton.oembed","provider":"Furnace Direct","version":"1.0","type":"link"}