{"title":"Condensate Float Switches","description":"\u003cp\u003eCondensate float switches shut the system down before a blocked drain overflows the pan and reaches your ceiling. A few dollars of insurance against an expensive water-damage claim.\u003c\/p\u003e","products":[{"product_id":"condensate-float-switch-97087","title":"Condensate Float Switch | 97087","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e97087\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e97087\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years. Most HVAC companies charge $150-250 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a condensate float switch?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $150-250 for this repair, including the service call. The part itself is $69.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271380799791,"sku":"97087","price":69.95,"currency_code":"USD","in_stock":true}]},{"product_id":"condensate-float-switch-96106","title":"Condensate Float Switch | 96106","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e96106\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e96106\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years. Most HVAC companies charge $150-250 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a condensate float switch?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $150-250 for this repair, including the service call. The part itself is $53.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271380832559,"sku":"96106","price":53.95,"currency_code":"USD","in_stock":true}]},{"product_id":"condensate-float-switch-83210","title":"Condensate Float Switch | 83210","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e83210\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e83210\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years. Most HVAC companies charge $150-250 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a condensate float switch?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $150-250 for this repair, including the service call. The part itself is $111.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271380865327,"sku":"83210","price":111.95,"currency_code":"USD","in_stock":true}]},{"product_id":"condensate-float-switch-97085","title":"Condensate Float Switch | 97085","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e97085\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e97085\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years. Most HVAC companies charge $150-250 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a condensate float switch?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $150-250 for this repair, including the service call. The part itself is $80.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271380898095,"sku":"97085","price":80.95,"currency_code":"USD","in_stock":true}]},{"product_id":"condensate-float-switch-46347400","title":"Condensate Float Switch | 46347400","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e46347400\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e46347400\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years. Most HVAC companies charge $150-250 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a condensate float switch?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $150-250 for this repair, including the service call. The part itself is $34.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271380930863,"sku":"46347400","price":34.95,"currency_code":"USD","in_stock":true}]},{"product_id":"condensate-float-switch-83230","title":"Condensate Float Switch | 83230","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e83230\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e83230\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years. Most HVAC companies charge $150-250 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a condensate float switch?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $150-250 for this repair, including the service call. The part itself is $110.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271380996399,"sku":"83230","price":110.95,"currency_code":"USD","in_stock":true}]},{"product_id":"condensate-float-switch-96100","title":"Condensate Float Switch | 96100","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e96100\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e96100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years. Most HVAC companies charge $150-250 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a condensate float switch?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $150-250 for this repair, including the service call. The part itself is $52.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271381029167,"sku":"96100","price":52.95,"currency_code":"USD","in_stock":true}]},{"product_id":"condensate-float-switch-207377","title":"Condensate Float Switch | 207377","description":"\u003cp\u003e\u003cstrong\u003eCondensate Float Switch\u003c\/strong\u003e — manufacturer part number \u003cstrong\u003e207377\u003c\/strong\u003e.\u003c\/p\u003e\n\u003ch2\u003eWhat this part does\u003c\/h2\u003e\u003cp\u003eThe float switch shuts your system down when the condensate drain backs up, before the water overflows the pan and reaches your ceiling or flooring. It is a few dollars of insurance against a very expensive water-damage claim.\u003c\/p\u003e\n\u003ch2\u003eReplace this part if\u003c\/h2\u003e\u003cul\u003e\n\u003cli\u003eWater pooling around the air handler or furnace\u003c\/li\u003e\n\u003cli\u003eSystem shuts off on humid days for no obvious reason\u003c\/li\u003e\n\u003cli\u003eDrain pan is full or overflowing\u003c\/li\u003e\n\u003cli\u003eCeiling staining below an attic air handler\u003c\/li\u003e\n\u003cli\u003eExisting switch is corroded or does not trip when lifted\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eManufacturer Part Number\u003c\/th\u003e\n\u003ctd\u003e207377\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCondition\u003c\/th\u003e\n\u003ctd\u003eNew\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSold By\u003c\/th\u003e\n\u003ctd\u003eFurnace Direct (Hamlin Mechanical LLC, MN Lic. #128688)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch2\u003eInstall difficulty\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEasy\u003c\/strong\u003e — about 20 minutes. Tools: Screwdriver, PVC cutter if plumbing in. Power off at the breaker: yes. Gas shutoff required: no.\u003c\/p\u003e\n\u003cp\u003eTypical service life is 5-8 years. Most HVAC companies charge $150-250 to replace this part, including the service call.\u003c\/p\u003e\n\u003ch2\u003eFrequently asked questions\u003c\/h2\u003e\n\u003ch3\u003eHow do I know if my condensate float switch is bad?\u003c\/h3\u003e\u003cp\u003eReplace it if you see any of these: water pooling around the air handler or furnace; system shuts off on humid days for no obvious reason; drain pan is full or overflowing.\u003c\/p\u003e\n\u003ch3\u003eCan I replace a condensate float switch myself?\u003c\/h3\u003e\u003cp\u003eYes. This is a easy repair that takes about 20 minutes with screwdriver, pvc cutter if plumbing in. Always shut the power off at the breaker first.\u003c\/p\u003e\n\u003ch3\u003eHow long does a condensate float switch last?\u003c\/h3\u003e\u003cp\u003eTypically 5-8 years in normal residential use. Heavy cycling, poor airflow, and dirty filters all shorten that.\u003c\/p\u003e\n\u003ch3\u003eHow much does a contractor charge to replace a condensate float switch?\u003c\/h3\u003e\u003cp\u003eMost HVAC companies charge $150-250 for this repair, including the service call. The part itself is $100.95.\u003c\/p\u003e\n\u003ch3\u003eHow fast does this ship?\u003c\/h3\u003e\u003cp\u003eOrders placed by 2 PM CT typically ship the same business day, with delivery in 1-5 business days.\u003c\/p\u003e\n\u003ch3\u003eWhat if it does not fit?\u003c\/h3\u003e\u003cp\u003eReturn it within 90 days. If you are unsure before ordering, call (888) 762-1334 — we are licensed HVAC contractors and can confirm the right part for your model.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSold by licensed HVAC contractors.\u003c\/strong\u003e Furnace Direct is Hamlin Mechanical LLC, Minnesota licence #128688. If this part does not fix the problem, call (888) 762-1334 and we will help you work out what will.\u003c\/p\u003e","brand":"Furnace Direct","offers":[{"title":"Default Title","offer_id":58271381061935,"sku":"207377","price":100.95,"currency_code":"USD","in_stock":true}]}],"url":"https:\/\/furnace.direct\/es\/collections\/float-switches\/2-5-ton.oembed","provider":"Furnace Direct","version":"1.0","type":"link"}